Power Quality Analyzer
Fixed PQ Meters
a)PQ Meter- MAVOLOG
Main Features:
- 12.5 A and 1000 V RMS
- Can be used in railway, mains supply and onboard electrical systems
- Continuous sampling of voltage ad current measurement inputs at 32 kHz per channel
- 2 analog inputs – e.g. for temperature, direct sunlight and wind speed
- 2 analog outputs – for selectable measured quantities
- 8 digital inputs – e.g. for switching statuses
- 8 digital outputs – e.g. for rate meter pulses and masked alarms
- Up to the 63rd harmonic
- Acquisition of 10 user-defined sub-harmonics
- Ethernet, USB (type B), RS 232 / RS 485; TCP/IP, Modbus and DNP3
- For various voltage levels
- Acquisition of energy flow patterns
- Ascertainment of current consumption
- Transparence for energy costs with assignment to cost centers
- Avoidance of peak loads
- Monitoring by means of numerous alarms / shutdowns of consuming devices in case of overload
- Ascertainment of more than 200 different mains quantities
- Acquisition of all measured voltage quantities per IEC/EN 61000-4-30 (class A)
- Evaluation of measurement data per EN 50160 (mains quality standard)
- Fast reaction to events
- By means of continuous monitoring
- Potential savings thanks to detection of reactive power generators and power guzzlers
4 current and 4 voltage measurement inputs with auto-ranging
Frequency range: 16 to 400Hz
High resolution

Up to 20 additional inputs and outputs
Spectral analysis in accordance with EN 61000-4-7
Communications interfaces and protocols
Extended flicker measurement per EN 61000-4-15

Range of Applications:
Power analysis in low, medium and high-voltage systems
Protection and monitoring function for machines, systems and electrical installations
Monitoring analysis and recording of relevant mains quantities
Clarification of disturbances
Minimization of the risk of failure and downtime
Energy cost management
b) PQ Meter- MAVOSYS
MAVOSYS 10 - Switchgear Mount Version Modular System for Power Quality, Demand & Energy Monitoring


MAVOSYS 10 SPECIFICATIONS
MODULES - CHOOSE UP TO FOUR
VOLTAGE
- Channels: (4) differential inputs, AC/DC
- Sampling: 512 samples/cycle, 16bit A/D, synchronous sampling
- Range: 1-600 Vrms, +/- 1000VPK, Frequency: 16/20Hz,50Hz, 60Hz
- Full Scale Accuracy: 0-600V 0.1% reading +/- 0.05% full scale, 7KHz bandwidth for low/medium frequency transients.100-300V AC 0.1% reading for IEC61000-4-30
- Input impedance: 10M Ohm to ground
- Choice of connections: Screw terminals (M819G), safety connectors (M819H), D connector (M819I) for use with (optional) remote pod with screw terminals (M819K).
- Channels: (4) differential inputs, AC/DC
- Sampling 512 samples/cycle, 16-bit A/D.
- Range: Full scale current = 1.5Vrms, crest factor of 3
- Accuracy: 0.1% reading +/- 0.05% full scale, 3KHz bandwidth for low/medium frequency transients. Does not include CT.
- Choice of connections: Screw terminals 1A (M819L) or 5A (M819M), TR connectors (M819N), D connector (M819I) for use with (optional) remote 1A 5 fold overload (M819P) or 5A 5 fold overload (M819Q) or 5A 20 fold overload (M819O).
- Channels: (8), Range: 0 – 135VAC/DC
- 1KHZ sampling, Edge or level triggered
- Logic programmed by user (active high or active low
- Time stamped to the millisecond
- Screw terminals (M819S)
- 1GB internal flash
- IEC61000-4-30 Class A, IEC61000-4-7, IEC61000-4-15
- EN50160, NVE, IEEE1159, IEEE1453, IEEE519, IEEE1459
- Standard: RJ45 TCP/IP Ethernet, RS232/RS485
- Optional: GSM/GPRS modem (Z819D), analog modem
- Protocols: XML, Modbus TCP/RTU
- Time synchronization: NTP, optional internal GPS (M819D)
- Standard: 90 to 250V AC 50/60Hz, 105 to 125V DC
- Optional: 90 to 250V AC/DC, 50/60Hz
- Screw terminals
- 15-minute internal UPS (specified with display & 4 modules)
- Panel Mount, 186mm x 186mm cutout
- M819C (61SGD): with ¼ VGA color touch display, 12 languages
- M819B (61SG): without display
- Z819I (61RMTSG): rack mount
- Operating temperature: -10 to 60˚C
- Humidity: 10 to 95%, non-condensing, Indoor use only
- CE, ISO9001
CURRENT
DIGITAL INPUT
MEMORY
MONITORING COMPLIANCE
COMMUNICATIONS
INSTRUMENT POWER
AVAILABLE ENCLOSURES
ENVIRONMENTAL
SAFETY
Portable PQ Analyzers
MAVOWATT 230, 240, 270 & 270-400 Power Quality Analyzers
FEATURE SUMMARY
- Portable analyzer for power quality, demand & energy analysis
- 7-inch wide screen colour touch LCD for easy operation
- IEC 61000-4-30:2008, class A, EN 50160 provides legally recognized measurements
- 1000 V CAT III, 600 V CAT IV, provides for a variety of applications
- Frequency range 15-20 Hz and 45-65 Hz for flexible use
- Communication via Ethernet, Wi-Fi, Bluetooth, USB for easy and safe data transfer
- Four current inputs (AC/DC) allow for the connection of flexible AC/DC current sensors
- Four symmetrical voltage channels (AC/DC, 50/60 Hz)
- Signal sampling with 512 samples per cycle
- Time synchronization via GPS and NTP
- Acquisition of sag/dip, swell, transients, unbalance, flicker
- Harmonics, Interharmonics, mains signaling
- Automatic report generation
- Mini reports allow for convenient preparation of user-defined protocols
- Dashboard function to monitor individual real-time values
- Integrated 4 GB flash memory, USB port for external memory devices
- VNC remote control for PC, Mac, IOS & Android
- Convenient data analysis by means of the easy-to-use Dranview® 7 software
- Rugged protective housing (IP 50) with easel and cable management
- Acquisition of transients in the micro second range (MAVOWATT 270, MAVOWATT 270-400)
- Intelligent Answer Modules ® allow for time-saving trouble shooting (MAVOWATT 240, MAVOWATT 270/-400)
- Inrush current, 10,000 recording cycles (MAVOWATT 240, MAVOWATT 270/-400)
- 400 Hz option for aviation, naval and military applications (MAVOWATT 270-400)
PQ Data Analytics Software- PQ View
PQView® is a database software application developed and commercialized by Electrotek Concepts, Inc. (“Electrotek”), which is designed to store and analyse large quantities of power quality-related disturbance and steady-state measurement data. PQView enables users to organize data from a variety of instruments, such as power quality monitors, voltage recorders, in-plant monitors, and fault recorders. It also stores site characteristics and event information. PQView brings all this information together in one relational database and provides the means to automate both the loading of new data and the generation of monitoring reports. PQView comes with a base set of reports that provide information on raw measurements, detailed statistical analysis, and executive summaries.
PQ View builds databases with billions of measurements from thousands of monitoring points taken by many different types of devises including power quality monitors, Disturbance recorders, protective relays, revenue meters, distribution SCADA. It can store, analyse and correlate information with the measurements about cause and source of triggered events as well as evaluate the financial impacts to both Power provider and power user. It can quickly extract meaning full information from a one megabyte or one terabyte database.
Software Structure PQ VIEW