• No.2, First Floor,8th
    Street,Nandanam Extension,
    Chennai - 600035
  • No.1073,15th Cross,
    30th Main, Banashankari
    2nd Stage, Bengaluru
  • Monday - Saturday
    9:30am - 6:30pm
    Sunday CLOSED

Power Lines

  • Home
  • .
  • Power Lines

SPDs for Power lines are available for AC (Three phase and Single phase) & DC applications. International Standards recommend. Zone wise protection for power lines, i.e different types of SPDs shall be provided at various levels of the power system namely, the Main switchboard, sub switchboard, near the equipment etc,. To make the protection simple & effective we are offering a wide range of SPDs. Few common SPDs are detailed below.

Power Lines Devices DMD3-65 MAG

SURGE PROTECTION DEVICE-Class I + II

Features

  • Plug- In protection modules for easy maintenance/ replacement.
  • Surge handling capability up to 65 kA.
  • Local Status Indication.
  • Provision for Remote monitoring.
  • Fits into most distribution box.

General Specifications


Surge Protection Device for 3phase with neutral (L-N, N-PE)
Nominal Voltage AC 50 Hz(U N ) 220 V
Maximum Continuous Operating voltage (L-N) (Uc) 275 V
Lightning Impulse Current (10/350) (I imp ) 12.5kA(L-N)/50kA(N-PE)
Maximum Discharge Current (8/20)(I max ) 65 kA
Nominal Discharge Current (8/20)(I n )(L-N) 30 kA
Nominal Discharge Current (8/20)(I n )(N-PE) 50 kA
Voltage Protection Level (L-N) (U p ) 1.2 kV @I n
Voltage Protection Level (N-PE) (U p ) 1.25 kV @I n
Power Lines Devices DMD3-50 MAG

SURGE PROTECTION DEVICE-Class II

Features



  • Plug- In protection modules for easy maintenance/ replacement.
  • Surge handling capability up to 50 kA.
  • Local Status Indication.
  • Provision for Remote monitoring.
  • Fits into most distribution box.

General Specifications


Surge Protection Device for 3 Phase(L-N,N-PE)
Nominal Voltage AC 50 Hz(U N) 220 V
Maximum Continuous Operating voltage (L-N) (U C) 275 V
Maximum Continuous Operating voltage (N-PE) (U C) 255 V
Lightning Impulse Current (10/350) (I imp ) 7.5kA(L-N)/25kA(N-PE)
Maximum Discharge Current (8/20)(I max ) 50 kA
Nominal Discharge Current (8/20)(I n )(L-N) 30 kA
Nominal Discharge Current (8/20)(I n )(N-PE) 50 kA
Voltage Protection Level (N-PE)(U p ) 1.2 kV @ I n
Voltage Protection Level (N-PE)(U p ) 1.25 kV @ I n


Power Lines Devices DMD3-30 MAG

SURGE PROTECTION DEVICE-Class II

Features



  • Plug- In protection modules for easy maintenance/ replacement.
  • Surge handling capability up to 30 kA.
  • Local Status Indication.
  • Provision for Remote monitoring.
  • Fits into most distribution box.

General Specifications


Surge Protection Device for 3 phase (L-N, N-PE)
Nominal Voltage AC 50 Hz(UN) 220 V
Maximum Continuous Operating voltage (L-N) (Uc) 275 V
Maximum Continuous Operating voltage (N-PE) (Uc) 255 V
Maximum Discharge Current (8/20)(Imax) 30 kA
Nominal Discharge Current (8/20)(In)(L-N) 20kA
Nominal Discharge Current (8/20)(In)(N-PE) 30 kA
Voltage Protection Level (L-N) 1.2 kV @ In
Voltage Protection Level (N-PE) 1.25 kV @ In


Power Lines Devices DMD1-30 MAG

SURGE PROTECTION DEVICE-Class II

Features



  • Plug- In protection modules for easy maintenance/ replacement.
  • Surge handling capability up to 30 kA.
  • Local Status Indication.
  • Provision for Remote monitoring.
  • Fits into most distribution box.

General Specifications


Surge Protection Device for L-N, N-PE protection
Nominal Voltage AC 50 Hz (UN) 220 V
Maximum Continuous Operating voltage (L-N) (Uc) 275 V
Maximum Continuous Operating voltage (N-PE) (Uc) 255 V
Maximum Discharge Current (8/20)(Imax) 30 kA
Nominal Discharge Current (8/20)(In)(L-N) 20 kA
Nominal Discharge Current (8/20)(In)(N-PE) 30 kA
Voltage Protection Level (L-N) 1.2 kV @ In
Voltage Protection Level (N-PE) 1.25 kV @ In


Power Lines Devices DMD1-30 MA/3

SURGE PROTECTION DEVICE-Class II

Features



  • Plug- In protection modules for easy maintenance/ replacement.
  • Surge handling capability up to 30 kA (8/20 µS)
  • Local Status Indication.
  • Provision for Remote monitoring.
  • Fits into most distribution box.

General Specifications


Surge Protection Device (L-N, N-PE)
Nominal Voltage AC 50 Hz(UN) 220 V
Maximum Continuous Operating voltage (Uc) 275 V
Maximum Discharge Current (8/20)(Imax) 30 kA
Nominal Discharge Current (8/20)( In) 20kA
Voltage Protection Level(Up) < 1.2 kV