OUR BUSINESS


AUDIT SERVICES
CONSULTING SERVICES
IEC 61400-24 is the dedicated international standard for wind turbine lightning protection. It works alongside the IEC 62305 series, which sets the general framework for risk assessment, protection measures, and surge protection. JEF Techno conducts lightning protection audits adhering strictly to IEC 61400-24.
Blade tips are the highest point on the turbine and often on the entire surrounding landscape. Almost all direct strikes land on the rotor blades, and research shows blade rotation can itself launch upward leaders and increase strike frequency.
Not on its own. A turbine requires blade receptors, a controlled current path across rotating bearings (pitch, yaw, and main shaft), zone-based surge protection (LPZ), and farm-level earthing, none of which a building-style design covers.
IEC 61400-24 recommends Lightning Protection Level I (LPL I), the highest standard, for all turbine sub-systems unless a detailed site risk analysis technically justifies a lower level.
Operators should follow the manufacturer's schedule and standard periodic maintenance, plus conduct an immediate inspection after any confirmed strike. Blade receptor and down-conductor continuity testing is crucial since receptors erode with each strike.
Yes. Receptors intercept the direct strike, but induced and conducted surges can still penetrate nacelle, hub, and tower-base electronics. Coordinated Type 1, 2, and 3 SPDs across every lightning protection zone boundary safeguard sensitive SCADA, control, and power electronics.